ROSEN Inspection Technologies
Coiled Tubing Inspection
   Inspection & Services       Data Services       Asset Integrity Management       Products for Sale       Customized Solutions       Company       Media Archives   
   Cleaning       In-Line Inspection       Robotic Inspection       Plant & Facility Inspection       Hydrostatic Testing & Commissioning   
  Automatic Coiled Tubing Integrity Monitoring (ACIM)  

Measurement Principle
The basic element of the ACIM metal loss survey is the high-resolution Magnetic Flux Leakage (MFL) technology. The pipe wall is magnetized longitudinally to saturation level using the very latest permanent magnets. High magnetization levels are necessary to differentiate corrosion from other pipeline features such as hard spots, stress and strain variations and to minimize the effects of remanent magnetization and velocity.

The ACIM contains three magnetic circuits and the MFL sensors placed around the coiled tubing. In the presence of internal and external metal loss, the flux “leaks” out of the pipeline and is recorded by hall effect sensors, of which there can be hundreds. The sensor system and electronics developed and manufactured in-house guarantee high resolution and sensitivity with 360-degree full circumferential coverage with sensor spacing of less than 3 mm. High magnetization levels of >10 kA/m ensure the validity of the results.

 

www.roseninspection.net